Fuel Level Sensor EPSILON ES
|
|
Page 6 of 6
Technical characteristics
Digital
Description | Unit | Value | Notes |
General |
Valid values of electrical conductivity controlled by the fuel, not more then |
S/m
|
10-8
|
2
|
Temperatures range |
°C |
-40...+80 |
|
IP level protection of probe head |
IP68 |
|
Explosion proof certificate
|
Measurments |
The range of measured values of the position of the controlled fuel |
mm
|
From 10 to 910
|
1,3,4,5
|
The resolution of the measurement of diesel fuel in the static mode, not worse then |
mm
|
0,05
|
6
|
The basic allowable error level measurement in a static mode, not more then |
mm
|
0,5
|
7
|
The average period of measurement results in dynamic mode |
sec |
8 |
|
Bit code representation of measurement results |
bit |
10/12/16 |
Level (8) |
8 |
Temperature |
Power Supply |
Supply voltage, the operating range |
V |
7-50 |
Rated |
|
|
Current consumption |
mA |
5,5±0,5 |
At 12V |
2,5±0,2 |
At 24V |
Mode |
|
Long |
|
Acceptable impact of pulsed voltage on power circuits |
|
± 200V, 1sec
± 1100V, 1 msec |
9 |
Interface |
Digital |
|
RS-485 |
Basic |
RS-232 |
10 |
Analog |
|
|
11 |
Installation size and weight |
Execution of planting flange |
|
SAE,
5 holes. d=5mm |
12 |
Type the thread probe |
|
M25x1,5 |
|
Size of the hexagon wrench for the measuring head |
mm |
36 |
According to GOST 6424 |
The height of the measuring head over the surface of the tank, including the planting flange, not more then |
mm |
29 |
13, 14 |
Weight of the sensor, not more then |
g |
300 |
4, 14 |
Notes to table 2:
- For diesel fuel with a nominal value of ε = 2.1 as adopted pursuant to the basic «620» (620mm).
- Allows measurements to grade fuel with a high electrical conductivity.
- The position of the upper (maximum) value of the measured level corresponds to the upper edge of the drain hole of the probe.
- Performance over «620» are performed as an option.
- Allowed the shortening of the probe «the place» no restrictions on minimum length.
- When using 16-bit representation of measurement results.
- Require further adjustment of the temperature dependence of the dielectric constant of controlled fuels.
- Adjustment is performed by the manufacturer to order the sensor.
- These are issued in two formats: 16 and 10/12 bit. Bit depth 10 or 12 bit software switchable.
- The default value — 12 bits.
Satisfies the most stringent requirements of GOST 28751–90 (product class, the degree of hardness 4 to 24V on-board power supply).
- Possible on request.
- Possible execution on request with voltage output 0 — 5 V, current 0 — 20 mA or potentiometer.
- Other versions connecting flange and in agreement with the consumer.
- Does not include gasket.
For specified performance of the flange.
|